Pickering validates Series 620 high-voltage relay with partial discharge testing for EV charger testers
Summary
Pickering Electronics has developed a customized Series 620 high-voltage reed relay for an automated test equipment manufacturer, using partial discharge testing to validate insulation reliability. The segmented, encapsulated design targets higher isolation for applications including EV charging systems, semiconductor manufacturing and energy storage.
Pickering Electronics, which makes high-voltage reed relays for instrumentation such as EV charge point testers, has developed a customized Series 620 relay for an automated test equipment (ATE) manufacturer. Partial discharge (PD) testing was used to validate the relay's insulation.
The modified relay uses a segmented internal design intended to increase electrical isolation, and potting and resin encapsulation techniques intended to minimize internal voids and air gaps. Pickering is evaluating PD testing for its relays, starting with its Series 600 and Series 620 ranges.
The Series 600, which Pickering says is the world's most customizable high-voltage reed relay, offers switching voltages up to 12.5 kV, switching power up to 200 W and stand-off voltages up to 20 kV. The Series 620 is designed for specialized high-voltage requirements. The two ranges are intended for semiconductor manufacturing, medical equipment, energy storage, renewable energy and industrial automation. Pickering also offers the Series 600 for hipot testing, cable testing and EV charging systems.
Conventional high-voltage withstand testing can confirm that insulation survives a specified voltage without electrical breakdown, but may not reveal microscopic voids or air gaps within the insulation. Under sustained high-voltage stress, gas trapped in these voids can become ionized, causing partial discharges that progressively degrade insulation and may eventually lead to relay failure.
"Partial discharge testing allows us to detect this activity before complete electrical breakdown occurs, providing valuable insight into potential insulation weaknesses that conventional testing might miss," said Robert King, Reed Relay Product Manager at Pickering Electronics. "This helps us better understand and optimise the long-term reliability of our high-voltage reed relays."
Source: Pickering Electronics